Use of Anatomical Undercut in Adhesive Retained Orbital Prosthesis: An Alternative to Osseointegration to Improve Retention and Reduce Margin Gap.

dc.contributor.authorWadud, Asikul
dc.contributor.authorJamayet, Nafij Bin
dc.contributor.authorSrithavaj, Theerathavaj
dc.contributor.authorAlam, Mohammad Khursheed
dc.date.accessioned2016-12-20T11:00:07Z
dc.date.available2016-12-20T11:00:07Z
dc.date.issued2015
dc.description.abstractIntroduction: Poor retention, stability and margin gap due to excessive bone lose following surgery is one of the major problems of rehabilitation in orbital defect with adhesive retained orbital prosthesis. Presentation of Case: This clinical report describes a simplified technique for the fabrication of an adhesive retained silicone orbital prosthesis by proper evaluation and using of remaining tissue undercuts to achieve ideal fit and aesthetics in a patient who has severely loss orbital bone after the surgery. Discussion: Aesthetics will be compromised if the proper evaluation of remaining tissue and treatment plan is not done prior prosthetic rehabilitation. To solve this issue sometimes maxillofacial prosthodontist may have to think for implant retained facial prosthesis. This is also sometime not possible due to several factors such as peri-implantitis, hygiene practice and dose of radiation etc. Conclusion: Proper use of remaining anatomical undercuts can be an alternative way to overcome the issue.en_US
dc.identifier.citationWadud Asikul, Jamayet Nafij Bin, Srithavaj Theerathavaj, Alam Mohammad Khursheed. Use of Anatomical Undercut in Adhesive Retained Orbital Prosthesis: An Alternative to Osseointegration to Improve Retention and Reduce Margin Gap. British Journal of Medicine and Medical Research. 2015; 6(8): 841-847.en_US
dc.identifier.urihttps://imsear.searo.who.int/handle/123456789/180166
dc.language.isoenen_US
dc.source.urihttps://www.sciencedomain.org/metrics/7712en_US
dc.subjectUndercuten_US
dc.subjectorbital prosthesisen_US
dc.subjectadhesiveen_US
dc.subjectmargin gapen_US
dc.subjectretentionen_US
dc.subjectstabilityen_US
dc.titleUse of Anatomical Undercut in Adhesive Retained Orbital Prosthesis: An Alternative to Osseointegration to Improve Retention and Reduce Margin Gap.en_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
bjmmr2015v6n8p841.pdf
Size:
536.57 KB
Format:
Adobe Portable Document Format
Description:
Case study
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: