Comparison of Conventionally Measured Serum Bicarbonate Values with Bicarbonate Values Obtained in Arterial and Venous Blood Gas Analysis.

dc.contributor.authorNargis, W
dc.contributor.authorAhamed, B U
dc.contributor.authorHossain, Z
dc.contributor.authorZabeen, S
dc.contributor.authorHouqe, N
dc.date.accessioned2015-12-05T09:07:13Z
dc.date.available2015-12-05T09:07:13Z
dc.date.issued2012
dc.description.abstractBicarbonate (HCO3-) measurement in serum or plasma from a sample of venous blood is routinely practiced in hospital patient management. HCO3- status can also be assumed from Blood gas analysis requiring arterial blood as sample which is cumbersome for both patients and doctors. This study was undertaken to evaluate the extent of agreement among biocarbonate values obtained during venous, arterial blood gas analysis and conventionally measured serum bicarbonate levels in a group of intensive care unit (ICU) patients to determine whether conventionally measured serum HCO3- (from peripheral venous blood) and calculated HCO3-values (from arterial blood gas [ABG] analyzers) can be used interchangeably. A total of 51 adult patients with diverse medical conditions, presenting at a tertiary health centre ICU were enrolled in this study when deemed by the treating physician to have an ABG analysis. Arterial and venous samples were taken as close in time as possible for blood gas analysis and routine blood tests. Bland-Altman analyses were used to compare the three methods. The HCO3- levels from ABG, Venous Blood gas (VBG) and tconventionally measured serum HCO3- showed acceptably narrow 95% limits of agreement using the Bland-Altman method. VBG reveals higher level of agreement with the ABG bicarbonate values compared to measured serum HCO3-. Thus, venous blood can be an alternate for arterial blood where ABG analyzer is available. conventionaly serum HCO3- measurements can also be useful and used as substitute for an expensive ABG analyzer in resource constrained health care sectors when required.en_US
dc.identifier.citationNargis W, Ahamed B U, Hossain Z, Zabeen S, Houqe N. Comparison of Conventionally Measured Serum Bicarbonate Values with Bicarbonate Values Obtained in Arterial and Venous Blood Gas Analysis. Bangladesh Journal of Medical Biochemistry. 2012; 5(1): 12-15.en_US
dc.identifier.issn2073-9915
dc.identifier.issn2408-8331
dc.identifier.urihttps://imsear.searo.who.int/handle/123456789/167223
dc.language.isoenen_US
dc.source.urihttps://banglajol.info/index.php/BJMB/article/view/13425en_US
dc.subjectArterial blood gas analysisen_US
dc.subjectVenous blood gas analysisen_US
dc.subjectMeasured serum bicarbonateen_US
dc.subjectIntensive Care Uniten_US
dc.titleComparison of Conventionally Measured Serum Bicarbonate Values with Bicarbonate Values Obtained in Arterial and Venous Blood Gas Analysis.en_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
bjmb2012v5n1p12.pdf
Size:
243.26 KB
Format:
Adobe Portable Document Format
Description:
Original article
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: