Effect Of Different Digital Impression Techniques On Marginal Fit Of Zirconia Crowns

dc.contributor.authorElfar, Mahmouden_US
dc.contributor.authorAlzafarani, Leenaen_US
dc.contributor.authorAlzafarani, Farahen_US
dc.date.accessioned2025-05-14T09:37:34Z
dc.date.available2025-05-14T09:37:34Z
dc.date.issued2024-12
dc.description.abstractPurpose: This study was performed to evaluate the effect of different methods of digital impression techniques on the marginal adaptation of monolithic zircon crown restorations. Three groups of zirconia crowns,Materials and Methods: 10 crowns in each group, were as follows:1)First group (G1) :Optical scanningof the stainless steel die (represent the natural tooth) using Zirkonzahn S600 ARTI®.optical scanner after it is sprayed with scanning spray gave us an optical impression from which we fabricated zirconium crowns directly. 2)Second group (G2): Polyvinylsiloxane impression material was used for fabrication of the conventional impression then digitized by optical scanning, then CAD/CAM was used to get zirconium crowns. 3)Third group (G3): Dental stone die, was scanned to produce the zirconium crowns. Results: The marginal gap (M ± S.D., ?m) of zirconia crowns fabricated using the digital impression for the master die (G1) was 21.62 ± 9.62, those fabricated from scanning the conventional impression (G2) was 22.13 ± 8.48, and those fabricated from scanning the stone die (G3) was 18.30 ± 7.18. A one-way ANOVA test was used to compare the marginal gaps of the three groups, where the P value was 0.09. It was considered that there is no-significant difference between them. While there was no significant difference, the highest marginal gap was observed in the crowns fabricated from conventional impression scanning (Group II), and the lowest gap was observed in the crowns fabricated from stone die scanning (Group III). HO: There is no difference in the marginal fit of the three groups of crownResearch hypotheses: restorations. HA: There is a difference in the marginal fit of the three groups.en_US
dc.identifier.affiliationsNova Southeastern University School Of Dental Medicineen_US
dc.identifier.affiliationsStony Brook University College of Arts and Sciencesen_US
dc.identifier.affiliationsBrentwood High School NY.en_US
dc.identifier.citationElfar Mahmoud, Alzafarani Leena, Alzafarani Farah . Effect Of Different Digital Impression Techniques On Marginal Fit Of Zirconia Crowns. Paripex - Indian Journal Of Research. 2024 Dec; 13(12): 71-75en_US
dc.identifier.issn2250-1991
dc.identifier.placeIndiaen_US
dc.identifier.urihttps://imsear.searo.who.int/handle/123456789/247876
dc.languageenen_US
dc.publisherINDIAN SOCIETY FOR HEALTH AND ADVANCED RESEARCHen_US
dc.relation.issuenumber12en_US
dc.relation.volume13en_US
dc.source.urihttps://www.doi.org/10.36106/paripex/5906583en_US
dc.subjectCAD/CAMen_US
dc.subject3D printingen_US
dc.subjectmonolithic zirconiumen_US
dc.subjectoptical impression techniques.en_US
dc.titleEffect Of Different Digital Impression Techniques On Marginal Fit Of Zirconia Crownsen_US
dc.typeJournal Articleen_US