Evaluation of Technical Parameter on CT-scan used for Pediatric and Adult Diagnosis in Two Governmental Referal Hospitals in Ethiopia

dc.contributor.authorDefersha, Alemu Motumaen_US
dc.contributor.authorTeferi, Siefeen_US
dc.contributor.authorRegasa, Destaen_US
dc.contributor.authorWase, Amanen_US
dc.date.accessioned2025-06-18T11:54:20Z
dc.date.available2025-06-18T11:54:20Z
dc.date.issued2025-02
dc.description.abstractThe main aim of this study was to reveal technical parameters on CT scan used for pediatric and adult diagnosis in Tikur Anbesa and Yekatit 12 specialized hospitals in Addis Ababa, Ethiopia. Thus, KV, mA, Eff.mAs, pitch, table feed and rotation times were among explored technical parameters in line of three leading questions. Data on head, neck, chest, abdomen and the pelvic scan regions were collected from a total of 154 patients (22 pediatrics and 132 adults). The data were analyzed through descriptive statistics on microsoft excel and t-test using SPSS software 21 version. The results were presented in the table, line graph and histogram. From t-test report results, it could have concluded that the ED from pediatric resulted in higher than that of adult, t (139)=-0.539, P=0.591. And pitch from pediatric scored higher than that of adult, t (139)=0.385, P=0.701. And for different scan regions and ages 120 KV was used and pediatric exposed to high radiation dose. Based on these results the following recommendations were made. The medical technologist should have selected the appropriate KV based on age and scan regions. The Ethiopian radiation authority should have made survey study on diagnosis dose to reduce the adverse health impacts of doses. Relevant authorities should monitor the radiation management implementation in CT scan medical imaging procedure in hospitals where CT scan machines are employed.en_US
dc.identifier.affiliationsDepartment of Medical Physics, Salale University, Fiche, Ethiopiaen_US
dc.identifier.affiliationsDepartment of Medical Physics, Addis Abeba University, Addis Ababa, Ethiopiaen_US
dc.identifier.affiliationsDepartment of Material Physics, Salale University, Fiche, Ethiopiaen_US
dc.identifier.affiliationsDepartment of Statistical and Computational Physics, University of Gondar, Gondar, Ethiopiaen_US
dc.identifier.citationDefersha Alemu Motuma, Teferi Siefe, Regasa Desta, Wase Aman. Evaluation of Technical Parameter on CT-scan used for Pediatric and Adult Diagnosis in Two Governmental Referal Hospitals in Ethiopia. International Journal of Medical Research & Health Sciences. 2025 Feb; 14(2): 1-13en_US
dc.identifier.issn2319-5886
dc.identifier.placeIndiaen_US
dc.identifier.urihttps://imsear.searo.who.int/handle/123456789/249679
dc.languageenen_US
dc.publisherSumathi Publicationsen_US
dc.relation.issuenumber2en_US
dc.relation.volume14en_US
dc.source.urihttps://www.ijmrhs.com/medical-research/evaluation-of-technical-parameter-on-ctscan-used-for-pediatric-and-adult-diagnosis-in-two-governmental-referal-hospitals.pdfen_US
dc.subjectEffectsen_US
dc.subjectCT scanen_US
dc.subjectTechnical parametersen_US
dc.subjectDiagnosis dose descriptorsen_US
dc.titleEvaluation of Technical Parameter on CT-scan used for Pediatric and Adult Diagnosis in Two Governmental Referal Hospitals in Ethiopiaen_US
dc.typeJournal Articleen_US
Files
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
ijmrhs2025v14n2p1b.pdf
Size:
7.63 MB
Format:
Adobe Portable Document Format