Evaluation and comparison of different polymerization techniques, curing cycles, and thicknesses of two denture base materials

dc.contributor.authorPalaskar, Jayant Nen_US
dc.contributor.authorSingh, Suninten_US
dc.contributor.authorMittal, Sanjeeven_US
dc.date.accessioned2020-01-02T06:46:46Z
dc.date.available2020-01-02T06:46:46Z
dc.date.issued2019-07
dc.description.abstractPurpose: The study aimed to compare the effect of different materials, thicknesses, and polymerization methods and cycles, on the surface porosity of acrylic denture base resins. Materials and Methods: Conventional heat-polymerized polymethyl methacrylate (PMMA) and specially designed acrylic resin (Acron MC) were used to make 84 rectangular samples. They were divided into three groups to evaluate and compare the polymerization techniques, curing cycles, and thicknesses of the two denture base materials (28 samples each). Group A contained PMMA samples polymerized using water bath method (control group); Group B contained Acron MC samples polymerized by microwave method, and Group C contained PMMA samples polymerized by microwave method. Each group was further divided based on sample thickness and polymerization cycles. Each sample was scanned for surface porosity and area of each pore was measured using optical microscope. Data was analyzed using ANOVA, Bonferroni, and student t-tests. Unpaired student t-test was performed to compare the means of surface porosity with polymerization cycles and thicknesses among the groups. The power of study was kept at 80%. Results: Group C showed highest mean % of porosity depending on method of polymerization, different polymerization cycles (short and long) and polymerization cycles within the group. Group B showed the highest mean % of porosity depending on thickness and thickness within the groups. Conclusions: Microwavable acrylic resin polymerized by microwave energy exhibited statistically insignificant increase in porosity when compared to conventional heat cured acrylic resin by water bath method. Conventional acrylic resin polymerized by microwave energy exhibited high statistically significant porosity irrespective of sample thickness. There was statistically insignificant increase in porosity depending on sample thickness irrespective of material and method of polymerization.en_US
dc.identifier.affiliationsDepartment of Prosthodontics, Sinhgad Dental College and Hospital, Pune, Maharashtra, Indiaen_US
dc.identifier.affiliationsDepartment of Prosthodontics, Dr. Harvansh Singh Judge Institute of Dental Sciences and Hospital, Punjab University, Sector 23, Chandigarh, Punjab, Indiaen_US
dc.identifier.affiliationsDepartment of Prosthodontics, M.M. College of Dental Sciences and Research, Mullana, Ambala, Haryana, Indiaen_US
dc.identifier.citationPalaskar Jayant N, Singh Sunint, Mittal Sanjeev. Evaluation and comparison of different polymerization techniques, curing cycles, and thicknesses of two denture base materials. Indian Journal of Dental Research. 2019 Jul; 30(4): 583-589en_US
dc.identifier.issn0970-9290
dc.identifier.issn1998-3603
dc.identifier.placeIndiaen_US
dc.identifier.urihttps://imsear.searo.who.int/handle/123456789/192281
dc.languageenen_US
dc.publisherIndian Society for Dental Researchen_US
dc.relation.issuenumber4en_US
dc.relation.volume30en_US
dc.source.urihttps://dx.doi.org/10.4103/ijdr.IJDR_170_16en_US
dc.subjectAcrylic resinen_US
dc.subjectmicrowave polymerizationen_US
dc.subjectoptical microscopeen_US
dc.subjectpoly methyl methacrylateen_US
dc.subjectporosityen_US
dc.titleEvaluation and comparison of different polymerization techniques, curing cycles, and thicknesses of two denture base materialsen_US
dc.typeJournal Articleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
ijdr2019v30n4p583.pdf
Size:
2.63 MB
Format:
Adobe Portable Document Format