BisGMA and TEGDMA Elution from Two Flowable Nanohybrid Resin Composites: An In vitro Study.

dc.contributor.authorHegde, Mithra N
dc.contributor.authorWali, Ankita
dc.date.accessioned2016-03-17T04:59:32Z
dc.date.available2016-03-17T04:59:32Z
dc.date.issued2015
dc.description.abstractAim: The aim of our study was to evaluate the amount of release of BisGMA and TEGDMA from two commercially available enamel replacement composites; Tetric N-Flow™ and G-aenial Universal Flo™ over a period of 24 hours after polymerization with a standard LED Curing Unit. Methods and Materials: Two flowable nanohybrid composite materials; Tetric N-Flow™ (Ivoclar Vivadent AG, Liechtenstein) and G-aenial Universal Flo™ (GC, India) were investigated and grouped into two groups. Ten samples from each group were prepared by inserting the material into a standardized Teflon mould of size 2x2x2 mm. Each sample was cured with a LED curing unit for 20 seconds and was stored in 2 ml of Ethanol at room temperature. After 24 hours, the samples were removed from the storage medium (ethanol) and prepared for measurements. A reverse phase HPLC unit was used to detect the release of BisGMA and TEGDMA monomers from the prepared samples. The acquired measurements were obtained after testing them in a High Liquid Performance Chromatography Unit. The data obtained was statistically analyzed and the results revealed significant amount of release of TEGDMA as well as BisGMA Results: G-aenial Universal Flo™ showed significant release of both TEGDMA as well as BisGMA as compared to Tetric N- Flow™. The increase was by 0.5 units. Conclusion: Significant amount of release of TEGDMA as well as BisGMA was seen in both the composite materials after HPLC Unit analysis. This can help in the evaluation of cytoxicity to the soft tissues in the oral environment.en_US
dc.identifier.citationHegde Mithra N, Wali Ankita. BisGMA and TEGDMA Elution from Two Flowable Nanohybrid Resin Composites: An In vitro Study. British Journal of Medicine and Medical Research. 2015; 5(9): 1096-1104.en_US
dc.identifier.urihttps://imsear.searo.who.int/handle/123456789/176032
dc.language.isoenen_US
dc.source.urihttps://sciencedomain.org/abstract/6701en_US
dc.subjectBisGMAen_US
dc.subjectflowable compositesen_US
dc.subjectHPLC uniten_US
dc.subjectmonomer elutionen_US
dc.subjectTEGDMAen_US
dc.titleBisGMA and TEGDMA Elution from Two Flowable Nanohybrid Resin Composites: An In vitro Study.en_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
bjmmr2015v5n9p1096.pdf
Size:
327.55 KB
Format:
Adobe Portable Document Format
Description:
Original Research Article
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: