Plasma pharmacokinetics of a generic amoxycillin and the innovator brand: a comparison.
dc.contributor.author | Goonetilleke, A K | en_US |
dc.contributor.author | Munasingha, J M | en_US |
dc.contributor.author | Guruge, D S | en_US |
dc.contributor.author | Samaraweera, D S | en_US |
dc.contributor.author | Weerasena, O V | en_US |
dc.date.accessioned | 2009-05-28T05:15:37Z | |
dc.date.available | 2009-05-28T05:15:37Z | |
dc.date.issued | 1998-03-13 | en_US |
dc.description | The Ceylon Medical Journal. | en_US |
dc.description.abstract | OBJECTIVE: To compare the bioavailability and plasma pharmacokinetics of a generic brand of amoxycillin (State Pharmaceutical Manufacturing Coporation) selected from the lower price range, with that of the innovation brand (Amoxil, Beecham). DESIGN: Sixteen healthy adult volunteers were allotted to two groups and each group was given a test dose of amoxycillin from each brand. Blood samples were collected at 0, 2, 3 and 4 hours thereafter plasma levels were assayed using high performance liquid chromatography. RESULTS: Analysis of results show that the generic product had similar bioavailability and pharmacokinetics when compared with the innovator product. CONCLUSION: The quality assured generic amoxycillin tested had similar bioavailability as a more costly branded version. | en_US |
dc.description.affiliation | Department of Pharmacology, Faculty of Medical Sciences, University of Sri Jayewardenepura. | en_US |
dc.identifier.citation | Goonetilleke AK, Munasingha JM, Guruge DS, Samaraweera DS, Weerasena OV. Plasma pharmacokinetics of a generic amoxycillin and the innovator brand: a comparison. The Ceylon Medical Journal. 1998 Mar; 43(1): 16-8 | en_US |
dc.identifier.uri | https://imsear.searo.who.int/handle/123456789/48191 | |
dc.language.iso | eng | en_US |
dc.source.uri | https://www.infolanka.com/CMJhome/ | en_US |
dc.subject.mesh | Administration, Oral | en_US |
dc.subject.mesh | Adolescent | en_US |
dc.subject.mesh | Adult | en_US |
dc.subject.mesh | Amoxicillin --administration & dosage | en_US |
dc.subject.mesh | Area Under Curve | en_US |
dc.subject.mesh | Biological Availability | en_US |
dc.subject.mesh | Chromatography, High Pressure Liquid | en_US |
dc.subject.mesh | Drugs, Generic --administration & dosage | en_US |
dc.subject.mesh | Female | en_US |
dc.subject.mesh | Humans | en_US |
dc.subject.mesh | Male | en_US |
dc.subject.mesh | Penicillins --administration & dosage | en_US |
dc.subject.mesh | Reference Values | en_US |
dc.title | Plasma pharmacokinetics of a generic amoxycillin and the innovator brand: a comparison. | en_US |
dc.type | Comparative Study | en_US |
dc.type | Journal Article | en_US |
Files
License bundle
1 - 1 of 1