Comparative Study of Bisphenol A Release from Various Orthodontic Adhesive and Myofunctional Appliances - An In-Vitro Study.

dc.contributor.authorGaniger, Chanamallappa R.en_US
dc.contributor.authorPatil, Sahil Sainathen_US
dc.contributor.authorPawar, Renukaen_US
dc.contributor.authorPhaphe, Sandeshen_US
dc.contributor.authorRonad, Yusuf Ahammeden_US
dc.contributor.authorMane, Pratapen_US
dc.contributor.authorAgarwal, Nidhi Rohiten_US
dc.contributor.authorSathe, Tanuja Tanajien_US
dc.date.accessioned2020-11-18T10:18:36Z
dc.date.available2020-11-18T10:18:36Z
dc.date.issued2020-09
dc.description.abstractWe wanted to compare & evaluate, regularly used orthodontic materials including adhesives & myofunctional appliances for release of Bisphenol A. MethodsBisphenol - A release was assessed from two materials - orthodontic adhesive resin and heat cure acrylic resin [twin block]. Based on materials used, a total of 40 samples was assigned into two groups; Group A and Group B, each containing 20 samples. For Group A [orthodontic adhesive resin], metal brackets were bonded to 20 bicuspid teeth using adhesive resin and cured with LED light. For group B, 20 twin block appliances made from heat cured acrylic resin were used. Then, samples from both the groups were immersed in artificial saliva and then subjecting to thermal treatment from hot (60 ˚C) to cold (4 ˚C) temperatures, followed by shaking for 5 minutes. The samples were again shaken at (37 ˚C) and 1.0-mL aliquots were removed at 24 hours and 7 days after insertion. Gas chromatography / mass spectroscopy was used for the evaluation of leaching of bisphenol A from artificial saliva. ResultsSignificant results were found after 24 hours of analysis in both groups where 70 % samples from group A had bisphenol A release, whereas 80 % samples from group B had bisphenol A release. However, a non-significant result was obtained after 7 days where 20 % samples from group A had bisphenol A release whereas 60% samples from group B had bisphenol A release. The Heat cure acrylic group showed higher Bisphenol - A than that of orthodontic adhesive resin group. It was seen that the levels were lower than the reference dose which were calculated for daily consumption but were statistically significant. CoclusionsBisphenol A is considered as an endocrine disruptor. Degradation of orthodontic materials results in leaching of Bisphenol-A into oral cavity which is a clinical concern.en_US
dc.identifier.affiliationsDepartment of Orthodontics and Dentofacial Orthopaedics, School of Dental Sciences, Krishna Institute of Medical Sciences, Malkapaur, Karad, Maharashtra, India.en_US
dc.identifier.affiliationsDepartment of Orthodontics and Dentofacial Orthopaedics, School of Dental Sciences, Krishna Institute of Medical Sciences, Malkapaur, Karad, Maharashtra, India.en_US
dc.identifier.affiliationsDepartment of Orthodontics and Dentofacial Orthopaedics, School of Dental Sciences, Krishna Institute of Medical Sciences, Malkapaur, Karad, Maharashtra, India.en_US
dc.identifier.affiliationsDepartment of Orthodontics and Dentofacial Orthopaedics, School of Dental Sciences, Krishna Institute of Medical Sciences, Malkapaur, Karad, Maharashtra, India.en_US
dc.identifier.affiliationsDepartment of Orthodontics and Dentofacial Orthopaedics, School of Dental Sciences, Krishna Institute of Medical Sciences, Malkapaur, Karad, Maharashtra, India.en_US
dc.identifier.affiliationsDepartment of Orthodontics and Dentofacial Orthopaedics, School of Dental Sciences, Krishna Institute of Medical Sciences, Malkapaur, Karad, Maharashtra, India.en_US
dc.identifier.affiliationsDepartment of Orthodontics and Dentofacial Orthopaedics, School of Dental Sciences, Krishna Institute of Medical Sciences, Malkapaur, Karad, Maharashtra, India. 8Department of Orthodontics and Dentofacial Orthopaedics, School of Dental Sciences, Krishna Institute of Medical Sciences, Malkapaur, Karad, Maharashtra, India.en_US
dc.identifier.citationGaniger Chanamallappa R., Patil Sahil Sainath, Pawar Renuka, Phaphe Sandesh, Ronad Yusuf Ahammed, Mane Pratap, Agarwal Nidhi Rohit, Sathe Tanuja Tanaji. Comparative Study of Bisphenol A Release from Various Orthodontic Adhesive and Myofunctional Appliances - An In-Vitro Study.. Journal of Evolution of Medical and Dental Sciences. 2020 Sep; 9(36): 2593-2596en_US
dc.identifier.issn2278-4802
dc.identifier.issn2278-4748
dc.identifier.placeIndiaen_US
dc.identifier.urihttps://imsear.searo.who.int/handle/123456789/215151
dc.languageenen_US
dc.publisherAkshantala Enterprises Private Limiteden_US
dc.relation.issuenumber36en_US
dc.relation.volume9en_US
dc.source.urihttps://dx.doi.org//10.14260/jemds/2020/564en_US
dc.subjectBisphenol-Aen_US
dc.subjectAdhesive Resinen_US
dc.subjectAcrylic Resinen_US
dc.subjectOrthodonticsen_US
dc.titleComparative Study of Bisphenol A Release from Various Orthodontic Adhesive and Myofunctional Appliances - An In-Vitro Study.en_US
dc.typeJournal Articleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
jemds2020v9n36p2593.pdf
Size:
563.31 KB
Format:
Adobe Portable Document Format