Unusual cause of hypoxemia after automatic implantable cardioverter‑defibrillatorleads extraction.

dc.contributor.authorRaju, Dinesh
dc.contributor.authorRoysam, Chandrika
dc.contributor.authorSingh, Rajendra
dc.contributor.authorClark, Stephen C
dc.contributor.authorPlummer, Christopher
dc.date.accessioned2015-11-07T06:58:44Z
dc.date.available2015-11-07T06:58:44Z
dc.date.issued2015-10
dc.description.abstractThe indication of pacemaker/AICD removal are numerous. Serious complication can occur during their removal, severe tricuspid regurgitation is one of the complication. The occurrence of PFO is not uncommon among adult population. Shunting across PFO in most circumstance is negligible, but in some necessitates closure due to hypoxemia. We report a case of 62 year old man, while undergoing AICD removal, had an emergency sternotomy for cardiac tamponade. Postoperatively, he experienced profound hypoxemia refractory to oxygen therapy. Transthoracic Echocardiogram was performed to rule out intracardiac shunts at an early stage, but it was difficult to obtain an good imaging windows poststernotomy. A small pulmonary emboli was noted on CTPA, but was not sufficient to account for the level of hypoxemia and did not resolve with anticoagulation. Transesophageal echocardiogram showed flail septal tricuspid valve with severe TR and bidirectional shunt through large PFO. Patient was posted for surgery, tricuspid valve was replaced and PFO surgically closed. Subsequently, patient recovered well ad was discharged to home. Cause of hypoxemia might be due to respiratory or cardiac dysfunction. But for hypoxemia refractory to oxygen therapy, transoesophageal echocardiogram should be always considered and performed early as an diagnostic tool in post cardiac surgical patients.en_US
dc.identifier.citationRaju Dinesh, Roysam Chandrika, Singh Rajendra, Clark Stephen C, Plummer Christopher. Unusual cause of hypoxemia after automatic implantable cardioverter‑defibrillatorleads extraction. Annals of Cardiac Anaesthesia. 2015 Oct; 18(4): 599-602.en_US
dc.identifier.urihttps://imsear.searo.who.int/handle/123456789/165277
dc.language.isoenen_US
dc.source.urihttps://www.annals.in/article.asp?issn=0971-9784;year=2015;volume=18;issue=4;spage=599;epage=602;aulast=Rajuen_US
dc.subjectAutomatic implantable cardioverter‑defibrillatoren_US
dc.subjectHypoxemiaen_US
dc.subjectTransesophageal echocardiogramen_US
dc.subjectPatent foramen ovaleen_US
dc.subjectTricuspid regurgitationen_US
dc.titleUnusual cause of hypoxemia after automatic implantable cardioverter‑defibrillatorleads extraction.en_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
aca2015v18n4p599.pdf
Size:
947.9 KB
Format:
Adobe Portable Document Format
Description:
Case report
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: