Bile leak detection by radionuclide scintigraphy.

dc.contributor.authorGupta, Ven_US
dc.date.accessioned2009-05-28T03:58:54Z
dc.date.available2009-05-28T03:58:54Z
dc.date.issued2006-01-08en_US
dc.descriptionKathmandu University Medical Journal.en_US
dc.description.abstractINTRODUCTION: Bile leak after liver injury has been reported to be a complication associated with significant mortality. Tc99m-IDA (Tc: Technetium) nuclear scan allows rapid and noninvasive diagnosis of bile leak. OBJECTIVE: An accidental case was referred for the detection of suspicious bile leak. METHODS: The ultrasound could not detect any abnormality. Dynamic Hepatobiliary Scintigraphy (DHBS) using radiolabeled tracer was performed. RESULTS: DHBS promptly detected the site of leak. CONCLUSION: This technique should be opted because it has been found to be quite sensitive, specific and accurate for detecting the bile leak, whereas, Ultrasound and CT imaging are less sensitive and nonspecific. Though, they are initially helpful in determining the presence of abdominal fluid collections, they are unable to differentiate between a seroma, lymphocele, hematoma or bile leak. Hepatobiliary scintigraphy is more accurate because it can demonstrate continuity of these fluid collections with the biliary tree. Further, hepatobiliary scintigraphy can provide real-time assessment of hepatocytes function and bile progression from the liver to the intestine.en_US
dc.description.affiliationNuclear Medicine and Thyroid Physician, Amritsar, India. drvjg@yahoo.comen_US
dc.identifier.citationGupta V. Bile leak detection by radionuclide scintigraphy. Kathmandu University Medical Journal. 2006 Jan-Mar; 4(1): 82-5en_US
dc.identifier.urihttps://imsear.searo.who.int/handle/123456789/46216
dc.language.isoengen_US
dc.source.urihttps://www.kumj.com.npen_US
dc.source.urihttps://kumj.com.np/ftp/issue/13/82-85.pdfen_US
dc.subject.meshAdulten_US
dc.subject.meshBile --radionuclide imagingen_US
dc.subject.meshHumansen_US
dc.subject.meshImino Acids --diagnostic useen_US
dc.subject.meshLiver --injuriesen_US
dc.subject.meshMaleen_US
dc.subject.meshOrganotechnetium Compounds --diagnostic useen_US
dc.subject.meshRadiopharmaceuticals --diagnostic useen_US
dc.titleBile leak detection by radionuclide scintigraphy.en_US
dc.typeCase Reportsen_US
dc.typeJournal Articleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
kumj2006v4n1p.82.pdf
Size:
270.58 KB
Format:
Adobe Portable Document Format
Description:
Journal article
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.79 KB
Format:
Plain Text
Description: