Balloon expandable stents for coarctation of the aorta: current status and technical considerations: case report.
dc.contributor.author | Durongpisitkul, Kritvikrom | en_US |
dc.contributor.author | Laohaprasitiporn, Duangmanee | en_US |
dc.contributor.author | Chanthong, Prakul | en_US |
dc.contributor.author | Panchavinnin, Pradit | en_US |
dc.date.accessioned | 2009-05-27T21:13:25Z | |
dc.date.available | 2009-05-27T21:13:25Z | |
dc.date.issued | 2005-02-21 | en_US |
dc.description | Chotmaihet Thangphaet. | en_US |
dc.description.abstract | BACKGROUND: Balloon expandable stents have been used to manage coarctation of the aorta (Co) in selected patients with very encouraging results. MATERIAL AND METHOD: The authors report here the first group of patients with Co who underwent a successful implantation of the new Palmaz Genesis stent with intermediate term follow up. RESULTS: There were 5 patients with an age range from 14 to 23 years old. All of them had significant Co and were receiving multiple anti-hypertensive medications. Primary stenting was performed in all patients. All of them had an immediate relief of the gradient. All antihypertensive medications were discontinued immediately in 4 patients. All patients had one year follow up which revealed a minimum gradient. One patient continues to receive oral antihypertensive medication. CONCLUSION: In patients with coarctation of the aorta (native or recoarctation of aorta), stent implantation may be a feasible and improved option to relieve the stenosis. Short and mid term followup of these patients have shown encouraging results. | en_US |
dc.description.affiliation | Division of Pediatric Cardiology, Department of Pediatrics, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok 10700, Thailand. sikdr@mahidol.ac.th | en_US |
dc.identifier.citation | Durongpisitkul K, Laohaprasitiporn D, Chanthong P, Panchavinnin P. Balloon expandable stents for coarctation of the aorta: current status and technical considerations: case report. Journal of the Medical Association of Thailand. 2005 Feb; 88(2): 269-74 | en_US |
dc.identifier.uri | https://imsear.searo.who.int/handle/123456789/44413 | |
dc.language.iso | eng | en_US |
dc.source.uri | https://www.mat.or.th/journal/all.php | en_US |
dc.subject.mesh | Adolescent | en_US |
dc.subject.mesh | Adult | en_US |
dc.subject.mesh | Aortic Coarctation --therapy | en_US |
dc.subject.mesh | Blood Vessel Prosthesis | en_US |
dc.subject.mesh | Blood Vessel Prosthesis Implantation --methods | en_US |
dc.subject.mesh | Female | en_US |
dc.subject.mesh | Humans | en_US |
dc.subject.mesh | Male | en_US |
dc.subject.mesh | Stents | en_US |
dc.subject.mesh | Treatment Outcome | en_US |
dc.title | Balloon expandable stents for coarctation of the aorta: current status and technical considerations: case report. | en_US |
dc.type | Case Reports | en_US |
dc.type | Journal Article | en_US |
Files
License bundle
1 - 1 of 1