Percutaneous device closure for Paravalvular leak- A single centre experience
| dc.contributor.author | Khanolkar, Uday B. | en_US |
| dc.contributor.author | Buch, Meemansa Kashyap | en_US |
| dc.contributor.author | Govind, Satish C. | en_US |
| dc.contributor.author | Raut, Barendra Kumar | en_US |
| dc.contributor.author | Raghuraman, Bagirath | en_US |
| dc.contributor.author | Kumawat, Kapil | en_US |
| dc.contributor.author | Mahala, Bijay Kumar | en_US |
| dc.contributor.author | Shenoi, Arjun | en_US |
| dc.contributor.author | Shetty, Devi Prasad | en_US |
| dc.date.accessioned | 2025-08-13T11:15:21Z | |
| dc.date.available | 2025-08-13T11:15:21Z | |
| dc.date.issued | 2025-06 | |
| dc.description.abstract | The incidence of paravalvular leak (PVL) following surgical valve replacement is 5–17%. Our main aim is to determine the safety and efficacy of percutaneous device closure for significant PVLs.Transcatheter device closure was done for 45 PVLs in 42 patients. PVLs were closed percutaneously in mitral position in 23 cases, in aortic position in 20 cases, and combined mitral and aortic leaks in 2 cases. We achieved a technical success rate of 93.33 % and procedural success rate of 91.11%. Transcatheter PVL closure is a safe and effective procedure for symptomatic PVLs. | en_US |
| dc.identifier.affiliations | Narayana Institute Of Cardiac Sciences, Bengaluru, India | en_US |
| dc.identifier.affiliations | Narayana Institute Of Cardiac Sciences, Bengaluru, India | en_US |
| dc.identifier.affiliations | Narayana Institute Of Cardiac Sciences, Bengaluru, India | en_US |
| dc.identifier.affiliations | Narayana Institute Of Cardiac Sciences, Bengaluru, India | en_US |
| dc.identifier.affiliations | Narayana Institute Of Cardiac Sciences, Bengaluru, India | en_US |
| dc.identifier.affiliations | Narayana Institute Of Cardiac Sciences, Bengaluru, India | en_US |
| dc.identifier.affiliations | Narayana Institute Of Cardiac Sciences, Bengaluru, India | en_US |
| dc.identifier.affiliations | Narayana Institute Of Cardiac Sciences, Bengaluru, India | en_US |
| dc.identifier.affiliations | Narayana Institute Of Cardiac Sciences, Bengaluru, India | en_US |
| dc.identifier.citation | Khanolkar Uday B., Buch Meemansa Kashyap, Govind Satish C., Raut Barendra Kumar, Raghuraman Bagirath, Kumawat Kapil, Mahala Bijay Kumar, Shenoi Arjun, Shetty Devi Prasad. Percutaneous device closure for Paravalvular leak- A single centre experience. Indian Heart Journal. 2025 Jun; 77(3): 235-242 | en_US |
| dc.identifier.issn | 0019-4832 | |
| dc.identifier.place | India | en_US |
| dc.identifier.uri | https://imsear.searo.who.int/handle/123456789/253344 | |
| dc.language | en | en_US |
| dc.publisher | Elsevier | en_US |
| dc.relation.issuenumber | 3 | en_US |
| dc.relation.volume | 77 | en_US |
| dc.source.uri | https://doi.org/10.1016/j.ihj.2025.02.008 | en_US |
| dc.subject | Paravalvular leak device closure | en_US |
| dc.subject | Transcatheter PVL closure | en_US |
| dc.subject | Paravalvular leak closure access | en_US |
| dc.subject | Valvular heart disease | en_US |
| dc.subject | Percutaneous PVL device closure | en_US |
| dc.title | Percutaneous device closure for Paravalvular leak- A single centre experience | en_US |
| dc.type | Journal Article | en_US |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- ihj2025v77n3p235.pdf
- Size:
- 6.74 MB
- Format:
- Adobe Portable Document Format