A Rare Case of Shone Complex, Where Coarctation was Treated Successfully with Covered Cheatham Platinum Stent

dc.contributor.authorSingla, R.en_US
dc.contributor.authorKaushikh, A.en_US
dc.contributor.authorKhemani, H.en_US
dc.contributor.authorSingh, G.en_US
dc.contributor.authorBansal, N. O.en_US
dc.date.accessioned2019-12-06T09:42:22Z
dc.date.available2019-12-06T09:42:22Z
dc.date.issued2019-05
dc.description.abstractShone complex is an extremely rare and severe congenital heart disease characterized by left -heart obstruction at multiple levels namely supravalvular mitral ring, parachute mitral valve, subaortic stenosis and coarctation of the aorta. We in the present case describe a patient of shone complex who underwent successful coarctoplasty with the help of BIB (balloon in balloon) dilatation catheter and covered CP (cheatham platinum) stent. The role of interventional cardiologist is to diagnose and choose the right approach for the specific patient, whether surgery, balloon or stent.en_US
dc.identifier.affiliationsDepartment of Cardiology, Sir JJ Hospitals and Grant Government Medical College, Mumbai, India.en_US
dc.identifier.affiliationsDepartment of Cardiology, Sir JJ Hospitals and Grant Government Medical College, Mumbai, India.en_US
dc.identifier.affiliationsDepartment of Cardiology, Sir JJ Hospitals and Grant Government Medical College, Mumbai, India.en_US
dc.identifier.affiliationsDepartment of Cardiology, Sir JJ Hospitals and Grant Government Medical College, Mumbai, India.en_US
dc.identifier.affiliationsDepartment of Cardiology, Sir JJ Hospitals and Grant Government Medical College, Mumbai, India.en_US
dc.identifier.citationSingla R., Kaushikh A., Khemani H., Singh G., Bansal N. O.. A Rare Case of Shone Complex, Where Coarctation was Treated Successfully with Covered Cheatham Platinum Stent. Cardiology and Angiology: An International Journal. 2019 May; 8(3): 1-5en_US
dc.identifier.issn2347-520X
dc.identifier.placeIndiaen_US
dc.identifier.urihttps://imsear.searo.who.int/handle/123456789/188684
dc.languageenen_US
dc.publisherScience Domain Internationalen_US
dc.relation.issuenumber3en_US
dc.relation.volume8en_US
dc.source.urihttps://doi.org/10.9734/ca/2019/v8i330100en_US
dc.subjectShone complexen_US
dc.subjectBIB (Balloon in Balloon) dilatation catheter and covered CP (Cheatham Platinum) stenten_US
dc.titleA Rare Case of Shone Complex, Where Coarctation was Treated Successfully with Covered Cheatham Platinum Stenten_US
dc.typeJournal Articleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
caij2019v8n3p1a.pdf
Size:
263.91 KB
Format:
Adobe Portable Document Format