Spurious automated red cell parameters due to cold agglutinins--a report of two cases.

dc.contributor.authorKakkar, Naveenen_US
dc.date.accessioned2004-04-22en_US
dc.date.accessioned2009-05-29T13:15:08Z
dc.date.available2004-04-22en_US
dc.date.available2009-05-29T13:15:08Z
dc.date.issued2004-04-22en_US
dc.description.abstractAlthough automation in hematology has resulted in improved accuracy of results, there are certain clinical conditions in which even the technologically advanced cell counters give out spurious results. It is therefore important that operators of these instruments are aware of these factitious results and the clues in the automated data that can be of help in identifying them. Two cases with spurious automated red cell parameters due to cold agglutinins are reported here.en_US
dc.description.affiliationDepartment of Pathology, Christian Medical College & Hospital, Ludhiana. n_kakkar@satyam.net.inen_US
dc.identifier.citationKakkar N. Spurious automated red cell parameters due to cold agglutinins--a report of two cases. Indian Journal of Pathology & Microbiology. 2004 Apr; 47(2): 250-2en_US
dc.identifier.urihttps://imsear.searo.who.int/handle/123456789/75453
dc.language.isoengen_US
dc.source.urihttps://www.ijpmonline.orgen_US
dc.subject.meshAdulten_US
dc.subject.meshAutomationen_US
dc.subject.meshCryoglobulins --metabolismen_US
dc.subject.meshErythrocyte Aggregationen_US
dc.subject.meshErythrocyte Indicesen_US
dc.subject.meshFemaleen_US
dc.subject.meshHematocriten_US
dc.subject.meshHumansen_US
dc.subject.meshMiddle Ageden_US
dc.titleSpurious automated red cell parameters due to cold agglutinins--a report of two cases.en_US
dc.typeCase Reportsen_US
dc.typeJournal Articleen_US