External quality assurance schemes in flow cytometry.

dc.contributor.authorLiu, T Cen_US
dc.date.accessioned2009-05-27T16:34:45Z
dc.date.available2009-05-27T16:34:45Z
dc.date.issued2002-12-21en_US
dc.descriptionThe Southeast Asian Journal of Tropical Medicine and Public Health.en_US
dc.description.abstractQuality assurance schemes were devised to monitor the performance of laboratory tests commonly utilized in routine clinical practice. In the area of Flow Cytometry, external quality assurance schemes are very much in their infancy. There are 3 major applications of Flow Cytometry in the clinical laboratory: lymphocyte subset enumeration, CD34 enumeration and leukemia immuno-phenotyping. Pilot schemes for CD34 enumeration and leukemia immuno-phenotyping have revealed a considerable lack of consensus with a wide divergence in practices. The coefficient of variation in reported results from these assessments have been very large, ranging from 20-200%. Results for lymphocyte subset enumeration surveys are sometimes not much better despite having been around for a longer period of time. Quality assurance programs in Flow Cytometry are difficult to conduct and 3 or 4 concurrent factors are often cited as reasons for the large variability. The need for viable, functionally intact cells as suitable assay material is probably the biggest contributor to the large variability. This difficulty in providing stable cells for inter-laboratory comparison is compounded by the lack of consensus in testing methodology. Participation in a distant external quality assurance scheme is consequently not very helpful to improving the practices in the laboratory. Currently, there are more problems than solutions. An awareness of these issues will hopefully contribute to the development of future consensus and offer up solutions to some of these problems.en_US
dc.description.affiliationDepartment of Laboratory Medicine, National University Hospital, Lower Kent Ridge Road, Singapore.en_US
dc.identifier.citationLiu TC. External quality assurance schemes in flow cytometry. The Southeast Asian Journal of Tropical Medicine and Public Health. 2002 ; 33 Suppl 2(): 91-3en_US
dc.identifier.urihttps://imsear.searo.who.int/handle/123456789/35534
dc.language.isoengen_US
dc.source.urihttps://www.tm.mahidol.ac.th/seameo/publication.htmen_US
dc.subject.meshFlow Cytometry --standardsen_US
dc.subject.meshHumansen_US
dc.subject.meshLaboratories --standardsen_US
dc.subject.meshQuality Assurance, Health Careen_US
dc.subject.meshSingaporeen_US
dc.titleExternal quality assurance schemes in flow cytometry.en_US
dc.typeJournal Articleen_US
Files
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.79 KB
Format:
Plain Text
Description: