Surgical removal of subfoveal perfluorocarbon liquid using combined flute needle and vacuum aspiration in silicone oil-filled eyes: A novel technique to remove subfoveal PFCL

dc.contributor.authorPan, Qen_US
dc.contributor.authorDeng, Yen_US
dc.contributor.authorWu, Wen_US
dc.contributor.authorZhao, Zen_US
dc.date.accessioned2020-04-10T02:00:48Z
dc.date.available2020-04-10T02:00:48Z
dc.date.issued2018-10
dc.description.abstractWe report a procedure using a pressure-controllable flute needle to remove subfoveal retention of perfluorocarbon liquid (PFCL) under silicone oil. With a two-port pars plana approach, we used a 27-gauge dental injection needle to create a retinotomy at the farthest edge of the PFCL bubble from the fovea. A 27-gauge flute needle was then inserted into the edge of the subfoveal PFCL to aspirate it with vacuum pressure. Three patients with subfoveal retained PFCL were treated by this procedure within silicone oil tamponade 1 month after the first operation. They promptly underwent successful removal of the PFCL with postoperative retinal reattachment and good visual outcome. This procedure allows safe and early treatment for subfoveal retained PFCL. Many medical institutions around the world could implement this procedure using common dental injection needles and flute needles.en_US
dc.identifier.affiliationsDepartment of Vitreoretinal Surgery, Eye Hospital of Wenzhou Medical University, Wenzhou, Zhejiang, Chinaen_US
dc.identifier.citationPan Q, Deng Y, Wu W, Zhao Z. Surgical removal of subfoveal perfluorocarbon liquid using combined flute needle and vacuum aspiration in silicone oil-filled eyes: A novel technique to remove subfoveal PFCL. Indian Journal of Ophthalmology. 2018 Oct; 66(10): 1463-1465en_US
dc.identifier.issn0301-4738
dc.identifier.issn1998-3689
dc.identifier.placeIndiaen_US
dc.identifier.urihttps://imsear.searo.who.int/handle/123456789/196919
dc.languageenen_US
dc.publisherAll India Ophthalmological Societyen_US
dc.relation.issuenumber10en_US
dc.relation.volume66en_US
dc.source.urihttps://dx.doi.org/10.4103/ijo.IJO_1337_17en_US
dc.subjectFlute needleen_US
dc.subjectsilicone oil-filled eyesen_US
dc.subjectsubfoveal perfluoracarbon liquiden_US
dc.subjectvacuum aspirationen_US
dc.titleSurgical removal of subfoveal perfluorocarbon liquid using combined flute needle and vacuum aspiration in silicone oil-filled eyes: A novel technique to remove subfoveal PFCLen_US
dc.typeJournal Articleen_US