Evaluation of Scheimpflug imaging system as an added tool in improving the accuracy of reference marking (as compared to the slit lamp marking system) for toric intraocular lens implantation

dc.contributor.authorSharma, Aen_US
dc.contributor.authorBatra, Aen_US
dc.date.accessioned2020-04-10T02:07:34Z
dc.date.available2020-04-10T02:07:34Z
dc.date.issued2020-04
dc.description.abstractPurpose: To assess the role of Scheimpflug imaging in improving the accuracy of reference marking for toric IOL implantation. Methods: In this prospective, randomized, clinical trial all patients with cataract and pre-existing significant regular corneal astigmatism, who required implantation of a toric IOL were included in the study, and patients with any ocular pathology or abnormality were excluded. Patients were divided into two groups: For one group of patients, Group I (GI), reference marking was finalized using slit lamp only, and for the second group, Group II (GII), after slit lamp marking, the reference marks were checked using Goniometer of Scheimpflug imaging. The primary outcome was to determine the axis of toric intraocular lens (IOL) postoperatively (within 1 hour) and compare it with the desired axis of placement. Results: We found a statistically significant difference in the two groups (P < 0.001) suggesting Group II (4 step technique) is better than Group I (3 step technique). Conclusion: Scheimpflug imaging, an extra step preoperatively, is an effective measure to reduce errors in reference marking and thereby improving the refractive outcome of toric intraocular lens.en_US
dc.identifier.affiliationsAmber Eye Care and Micro Surgery Centre, Thane, Maharashtra, Indiaen_US
dc.identifier.citationSharma A, Batra A. Evaluation of Scheimpflug imaging system as an added tool in improving the accuracy of reference marking (as compared to the slit lamp marking system) for toric intraocular lens implantation. Indian Journal of Ophthalmology. 2020 Apr; 68(4): 583-587en_US
dc.identifier.issn0301-4738
dc.identifier.issn1998-3689
dc.identifier.placeIndiaen_US
dc.identifier.urihttps://imsear.searo.who.int/handle/123456789/197899
dc.languageenen_US
dc.publisherAll India Ophthalmological Societyen_US
dc.relation.issuenumber4en_US
dc.relation.volume68en_US
dc.source.urihttps://dx.doi.org/10.4103/ijo.IJO_1253_19en_US
dc.subjectReference markingen_US
dc.subjectScheimpflug imagingen_US
dc.subjectslit lamp biomicroscopeen_US
dc.subjecttoric IOLen_US
dc.titleEvaluation of Scheimpflug imaging system as an added tool in improving the accuracy of reference marking (as compared to the slit lamp marking system) for toric intraocular lens implantationen_US
dc.typeJournal Articleen_US