Visual field assessment in glaucoma: comparative evaluation of manual kinetic Goldmann perimetry and automated static perimetry.
dc.contributor.author | Agarwal, H C | en_US |
dc.contributor.author | Gulati, V | en_US |
dc.contributor.author | Sihota, R | en_US |
dc.date.accessioned | 2000-12-09 | en_US |
dc.date.accessioned | 2009-05-29T09:12:57Z | |
dc.date.available | 2000-12-09 | en_US |
dc.date.available | 2009-05-29T09:12:57Z | |
dc.date.issued | 2000-12-09 | en_US |
dc.description.abstract | PURPOSE: To compare the detection and assessment of progression of visual field defects in primary open-angle glaucoma with manual suprathreshold perimetry on Goldmann perimeter and automated static threshold perimetry on Humphery visual field (HVF) analyzer. METHODS: 105 eyes of 54 patients of primary open-angle glaucoma were followed up with 3-monthly perimetry on Goldmann perimeter and HVF analyzer, for a period of 9 months. RESULTS: HVF analyzer picked up visual field defects in 48 (46%) eyes whereas Goldmann perimeter picked up visual field defects in 26 (25%) eyes. HVF analyzer demonstrated progression in 14 eyes whereas Goldmann perimeter detected progression in 7 eyes during follow up of 9 months. CONCLUSIONS: HVF analyzer is superior to Goldmann perimeter to document and to demonstrate progression of visual field defects in primary open-angle glaucoma. | en_US |
dc.description.affiliation | Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, Ansari Nagar, New Delhi-110 029, India. | en_US |
dc.identifier.citation | Agarwal HC, Gulati V, Sihota R. Visual field assessment in glaucoma: comparative evaluation of manual kinetic Goldmann perimetry and automated static perimetry. Indian Journal of Ophthalmology. 2000 Dec; 48(4): 301-6 | en_US |
dc.identifier.uri | https://imsear.searo.who.int/handle/123456789/71347 | |
dc.language.iso | eng | en_US |
dc.source.uri | https://www.ijo.in | en_US |
dc.subject.mesh | Adolescent | en_US |
dc.subject.mesh | Adult | en_US |
dc.subject.mesh | Aged | en_US |
dc.subject.mesh | Aged, 80 and over | en_US |
dc.subject.mesh | Automatic Data Processing | en_US |
dc.subject.mesh | Female | en_US |
dc.subject.mesh | Glaucoma, Open-Angle --diagnosis | en_US |
dc.subject.mesh | Humans | en_US |
dc.subject.mesh | Male | en_US |
dc.subject.mesh | Middle Aged | en_US |
dc.subject.mesh | Perimetry --methods | en_US |
dc.subject.mesh | Reproducibility of Results | en_US |
dc.subject.mesh | Severity of Illness Index | en_US |
dc.subject.mesh | Visual Fields --physiology | en_US |
dc.title | Visual field assessment in glaucoma: comparative evaluation of manual kinetic Goldmann perimetry and automated static perimetry. | en_US |
dc.type | Clinical Trial | en_US |
dc.type | Comparative Study | en_US |
dc.type | Evaluation Studies | en_US |
dc.type | Journal Article | en_US |
dc.type | Randomized Controlled Trial | en_US |
Files