Determination of time elapsed since death from the status of transparency of cornea in Ranchi in different weathers.

dc.contributor.authorKumar, Binay
dc.contributor.authorKumari, Vinita
dc.contributor.authorMahto, Tulsi
dc.contributor.authorSharma, Ashok
dc.contributor.authorKumar, Aman
dc.date.accessioned2013-03-21T03:55:48Z
dc.date.available2013-03-21T03:55:48Z
dc.date.issued2012-10
dc.description.abstractDetermination of ‘time elapsed since death’ (TSD) is one of the important content of the post-mortem report. Although the status of transparency of cornea is variable, depending on different factors like other parameters used for the purpose of determination of time since death but it is less variable as compared to others. The study sample comprised of 238 medico-legal autopsies conducted in the department of Forensic Medicine & Toxicology, Rajendra Institute of Medical Sciences, Ranchi, Jharkhand during June 2006 to September 2007. In majority of cases cornea remains transparent & moist in 0—06 Hrs and becomes transparent & dry in 06—12 Hrs, transparent to hazy in 12—24 Hrs, hazy to opaque in 24—36 hrs and opaque in >36 Hrs. In sequence, changes occurs more in warm & moist weather then in warm & dry weather and cold & moist weather respectively and least in cold and dry weather.en_US
dc.identifier.citationKumar Binay, Kumari Vinita, Mahto Tulsi, Sharma Ashok, Kumar Aman. Determination of time elapsed since death from the status of transparency of cornea in Ranchi in different weathers. Journal of Indian Academy of Forensic Medicine. 2012 Oct; 34(4): 336-338.en_US
dc.identifier.urihttps://imsear.searo.who.int/handle/123456789/145739
dc.language.isoenen_US
dc.source.urihttps://medind.nic.in/jal/t12/i4/jalt12i4p336.pdfen_US
dc.subjectCorneaen_US
dc.subjectTransparenten_US
dc.subjectHazyen_US
dc.subjectWarmen_US
dc.subjectColden_US
dc.subjectDryen_US
dc.subjectMoisten_US
dc.subjectTime Elapsed Since Death (TSD)en_US
dc.subject.meshAutopsy --legislation & jurisprudence
dc.subject.meshAutopsy --methods
dc.subject.meshCold Temperature
dc.subject.meshCornea --physiology
dc.subject.meshDeath
dc.subject.meshHot Temperature
dc.subject.meshHumans
dc.subject.meshIndia
dc.subject.meshPostmortem Changes
dc.subject.meshTemperature
dc.subject.meshTime Factors
dc.subject.meshWeather
dc.titleDetermination of time elapsed since death from the status of transparency of cornea in Ranchi in different weathers.en_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
jiafm2012v34i4p336.pdf
Size:
385.97 KB
Format:
Adobe Portable Document Format
Description:
Journal article
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: