Homocysteine and restenosis after percutaneous coronary intervention.

No Thumbnail Available
Date
2001-12-11
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
Numerous clinical studies in Western and Asian countries suggest that individuals with elevated blood levels of homocysteine have an increased risk of atherosclerosis, myocardial infarction, cerebral infarction, and deep vein thrombosis. Homocysteine is also known to induce both atherogenic and thrombogenic mediators in cultured vascular cells so that homocysteine may influence the damage of endothelial cells, promote smooth muscle cell growth, induce atherogenic mediators and thrombus formation after coronary angioplasty. The association between homocysteine and restenosis after percutaneous coronary intervention (PCI) has been discussed. In this study, the relationship between plasma homocysteine levels and restenosis after PCI to investigate whether plasma homocysteine levels may be a predictor of restenosis after PCI was examined. One hundred consecutive patients who underwent successful PCI were enrolled and plasma homocysteine level was measured in all patients prior to PCI. Plasma for homocysteine level was obtained in 99 of 100 patients who had angioplasty. The mean plasma homocysteine concentration in the enrolled patients was 13.61 +/- 6.04 micromol/L. The minimum and maximum of plasma homocysteine were 4.40 micromol/L and 50.00 micromol/L, respectively. In healthy subjects, the normal reference range of homocysteine level is 5-15 micromol/L However, recent data suggest that some patients may be at increased cardiovascular and cerebrovascular risk at levels as low as 12 micromol/L. For this reason, both cut off points of homocysteine level > or = 15 micromol/L or > or = 12 micromol/L to identify the high homocysteine level group were used. Of 99 patients, high homocysteine level (> or = 15 micromol/L) was established in 9 patients with restenosis versus 20 patients without restenosis. If the cut off point of homocysteine level > or = 12 micromol/L was used, high homocysteine level was established in 14 patients with restenosis versus 39 patients without restenosis. From both cut off points of homocysteine level, there was no correlation between plasma homocysteine level and the restenosis group. (p>0.05).
Description
Chotmaihet Thangphaet.
Keywords
Citation
Mahanonda N, Leowattana W, Kangkagate C, Lolekha P, Pokum S. Homocysteine and restenosis after percutaneous coronary intervention. Journal of the Medical Association of Thailand. 2001 Dec; 84 Suppl 3(): S636-44