Accidental cannulation of aberrant radial artery.

dc.contributor.authorSathish, N
dc.contributor.authorPrasad, S R
dc.contributor.authorNagesh, K S
dc.contributor.authorJagadeesh, A M
dc.date.accessioned2014-01-06T05:08:37Z
dc.date.available2014-01-06T05:08:37Z
dc.date.issued2014-01
dc.identifier.citationSathish N, Prasad S R, Nagesh K S, Jagadeesh A M. Accidental cannulation of aberrant radial artery. Annals of Cardiac Anaesthesia. 2014 Jan; 17(1): 76-77.en_US
dc.identifier.urihttps://imsear.searo.who.int/handle/123456789/149705
dc.language.isoenen_US
dc.source.urihttps://www.annals.in/article.asp?issn=0971-9784;year=2014;volume=17;issue=1;spage=76;epage=77;aulast=Sathishen_US
dc.subject.meshAnesthesia, Intravenous
dc.subject.meshCatherterization, Peripheral --adverse effects
dc.subject.meshHumans
dc.subject.meshMale
dc.subject.meshMedical Errors
dc.subject.meshRadial Artery --abnormalities
dc.subject.meshRadial Artery --injuries
dc.subject.meshRegional Blood Flow
dc.subject.meshWrist --blood supply
dc.subject.meshYoung Adult
dc.titleAccidental cannulation of aberrant radial artery.en_US