Repository logo
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Suomi
  • Svenska
  • Türkçe
  • Tiếng Việt
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Yкраї́нська
  • Log In
    New user? Click here to register.Have you forgotten your password?
Repository logo
  • Communities & Collections
  • All of DSpace
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Suomi
  • Svenska
  • Türkçe
  • Tiếng Việt
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Yкраї́нська
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Gupta, Sneha1"

Now showing 1 - 1 of 1
Results Per Page
Sort Options
  • Loading...
    Thumbnail Image
    Item
    Impact of tear optics on the repeatability of Pentacam AXL wave and iTrace in measuring anterior segment parameters and aberrations
    (All India Ophthalmological Society, 2022-04) Kundu, Gairik; Shetty, Rohit; Khamar, Pooja1; Gupta, Sneha1; Mullick, Ritika; Ganesan, Vaitheeswaran L2; D扴ouza, Sharon
    Purpose: To assess impact of tear optics on repeatability of a Scheimpflug device with a Hartmann Shack aberrometer and a ray tracing aberrometer. Methods: One hundred healthy and 100 postrefractive surgery eyes underwent dry eye evaluation including Schirmer抯 test and tear film break?up time (TBUT). They underwent optical quality analyzer (OQAS, Visio metrics S.L, Terrassa, Spain) to assess objective scatter index (OSI), three scans each on Pentacam AXL wave (OCULUS Optikgerate Gmbh, Wetzlar, Germany), iTrace (Tracey� Technologies, Texas, USA) for flat, steep keratometry, thinnest corneal thickness, root mean square higher?order aberrations (RMS HOA), RMS lower?order aberrations (LOA), spherical aberrations, RMS COMA. Repeatability of Pentacam AXL wave and iTrace in healthy and postrefractive eyes (OSI >1 vs OSI <1) was studied using within?subject standard deviation (Sw) test杛etest repeatability (TRT), coefficient of variation (COV). Results: OSI showed an inverse association with TBUT (P < 0.001). All measurements with Pentacam AXL wave with OSI < 1 had excellent repeatability, intraclass correlation coefficient (ICC) ranging from 0.88 for HOA, to 0.92 for LOA. The Sw, TRT, and COV of all aberration measurements were significantly lower (better) than those of iTrace. In eyes with OSI ?1, the repeatability with Pentacam AXL wave dropped with ICC ranging from 0.77 for HOA, to 0.84 for LOA with lower Sw, TRT, and COV of all aberration measurements as compared to iTrace. Maximum variation was seen with HOA and minimum with LOA. Conclusion: Tear optics affected repeatability of Pentacam wave and iTrace. Pentacam wave had better repeatability in eyes with a poor tear film as compared to iTrace. Thus, the tear film can impact repeatability of an instrument and it is important to assess the tear film prior to imaging patients, which can change the way we interpret and image these patients.

IMSEAR is the collaborative product of Health Literature, Library and Information Services (HELLIS) Network Member Libraries in the WHO South-East Asia Region.
HELLIS is coordinated by WHO Regional Office for South-East Asia.