Sundaram, SGunasekaran, K.Kalaiyarasan, A.2023-08-092023-08-092023-06Sundaram S, Gunasekaran K., Kalaiyarasan A.. STUDY ON THE EFFECT OF BRASS AND COPPER ELECTRODES DURING ELECTRIC DISCHARGE MACHINING OF INCONEL 718 USING NANO PARTICLES MIXED DIELECTRIC FLUID.. Indian Journal Of Applied Research. 2023 Jun; 13(6): 66-682249-555Xhttp://imsear.searo.who.int/handle/123456789/221449Electrical Discharge Machine (EDM) parameters have a significant influence on machining characteristic like material removal rate (MMR) and tool wear rate (TWR). Inconel 718, which is widely used in the Medical, Marine, Architectural and food processing industries, is used as a work material. The tool electrode materials used are brass and copper. Experiments are conducted using face centered central composite design to determine the effects of process parameters like current rate, pulse on time, pulse off time and concentration of titanium carbide nano particle in dielectric fiuid. Based upon the experimental outcomes, the effect of brass and copper electrodes during electric discharge machining of Inconel 718 using nano particles mixed dielectric fiuid was investigated.Electrical Discharge Machine (EDM)Brass and Copper ElectrodeTitanium Carbide Nano ParticleMaterial Removal Rate (MRR)Tool Wear Rate (TWR).STUDY ON THE EFFECT OF BRASS AND COPPER ELECTRODES DURING ELECTRIC DISCHARGE MACHINING OF INCONEL 718 USING NANO PARTICLES MIXED DIELECTRIC FLUID.Journal ArticleIndiaProfessor, Department of Mechanical Engineering, Muthayammal Engineering College, RasipuramProfessor, Department of Mechanical Engineering, Muthayammal Engineering College, RasipuramAssistant Professor, Department of Mechanical Engineering, Muthayammal Engineering College, Rasipuram.