Singh, DineshwarThakur, SitaSood, Ajay2020-10-162020-10-162020-06Singh Dineshwar, Thakur Sita, Sood Ajay. Evaluation of clinical outcome of post placental insertion of Cu T 380 A in women undergoing caesarean delivery. International Journal of Reproduction, Contraception, Obstetrics and Gynecology. 2020 Jun; 9(6): 2463-24692320-17702320-1789http://imsear.searo.who.int/handle/123456789/207772Background: The objective of the study was to evaluate clinical outcome of insertion of post placental Cu T 380 A in women undergoing caesarean delivery.Methods: A prospective observational study was carried out in the department of obstetrics and gynecology, Dr RPGMC Kangra at Tanda (Rural Medical College) to evaluate the clinical outcome of post placental Cu T 380 A insertion in women undergoing caesarean section after taking approval of protocol review and institutional ethics committee of the institution. A total of 104 women delivering by caesarean section and wanting post-placental intra-caesarean Cu T 380 A insertion and who were meeting WHO standard medical criteria for PPIUCD insertion and were willing to comply with the study protocol was recruited for the study.Results: The present study showed that there were no major complications and only minor side effects were like pain, fever, discharge and irregular bleeding which were observed in only 5-15% of women during hospital stay and during follow up visit up to 6 months. String became visible in 72.12% of women at the 6 weeks follow up visit. The string visibility increased with time and at 6 months follow up stings became visible in 90.81% of the cases. Continuation rate was 100% at 6 weeks post-partum follow up. After that spontaneous expulsion occurred in 4 cases (3.84%) and another 4 women (3.84%) requested removal for various reasons leading to continuation rate of 92.3% at six months post-partum follow up. There was no case of pregnancy with Cu T in situ with no failure at the end of study at six months post-partum.Conclusions: Intra caesarean insertion of PPIUCD is practical, convenient, safe, effective and acceptable contraceptive method for spacing of the birth in this rural setting.Clinical outcomesContinuationCu-T 380 AFamily planningIntrauterine contraceptive devicePostpartum contraceptionEvaluation of clinical outcome of post placental insertion of Cu T 380 A in women undergoing caesarean deliveryJournal ArticleIndiaDepartment of Obstetrics and Gynecology, Dr RPGMC Kangra at Tanda, Himachal Pradesh, India