Virmani, SanjulaUppal, RajeevKiro, KiranlataBhandari, HrichaDutta, DeveshSingh, NawabAggarwal, Anil2012-07-182012-07-182011-09Virmani Sanjula, Uppal Rajeev, Kiro Kiranlata, Bhandari Hricha, Dutta Devesh, Singh Nawab, Aggarwal Anil. Successful double lumen tube insertion in a patient with unanticipated laryngeal and tracheal web. Annals of Cardiac Anaesthesia. 2011 Sept; 14(3): 211-213.http://imsear.searo.who.int/handle/123456789/139612A 45-year-old female patient admitted for surgical management of carcinoma esophagus, presented with difficulty in insertion of left-sided 37 F and 35 F double lumen tube (Mallinckrodt® Broncho-Cath). Fiberoptic bronchoscopy revealed a subglottic web in the larynx just below the vocal cords and a tracheal web just above the carina. Differential lung ventilation could be achieved with a 35 F internal diameter double lumen tube (Portex® Blueline® Endobronchial tube).enDifficult intubationdouble lumen tubelaryngeal and tracheal websEsophageal Neoplasms --surgeryFemaleHumansIntubation, Intratracheal --instrumentationIntubation, Intratracheal --methodsLaryngeal Diseases --complicationsMiddle AgedTracheal Diseases --complicationsSuccessful double lumen tube insertion in a patient with unanticipated laryngeal and tracheal web.Article