Rapid fluorescent focus inhibition test for rabies antibody estimation using murine neuroblastoma cell line.
No Thumbnail Available
Date
1991-03-01
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
A rapid fluorescent focus inhibition test (RFFIT) for rabies antibody estimation has been standardized in which murine neuroblastoma cell line, Neuro-2A and tissue culture microtiter plates were used. Serum samples from 105 human beings, 30 canines, 7 rabbits and 4 monkeys were tested by RFFIT. Of these, 33 human and 20 canine sera were also tested by the mouse neutralization test (MNT). Twelve human sera were tested by RFFIT, MNT and ELISA. There was 94 per cent correlation between the results obtained by RFFIT and MNT, while in 6 per cent of the sera tested, the RFFIT was found to be more sensitive than the MNT.
Description
Keywords
Citation
Pandit V, Joseph LW, Veerabhadran JS, Palaniappan C. Rapid fluorescent focus inhibition test for rabies antibody estimation using murine neuroblastoma cell line. Indian Journal of Medical Research. 1991 Mar; 93(): 67-70