Conventional ESR V/S Automated VES- MATIC 20/20 Plus New ESR- A Comparative Study Of 100 Cases
| dc.contributor.author | Kaur, Mohanvir | en_US |
| dc.contributor.author | Mittal, Anika | en_US |
| dc.contributor.author | Poonam | en_US |
| dc.contributor.author | Puri, Arun | en_US |
| dc.date.accessioned | 2019-12-06T09:25:57Z | |
| dc.date.available | 2019-12-06T09:25:57Z | |
| dc.date.issued | 2018-03 | |
| dc.description.abstract | Background: To compare the ESR values by Ves- matic 20/20 plus new with the conventional Westergren method, aiming to validate the automated methods. Methods: A cross – sectional study was conducted in Government Medical College, Patiala. A total of 100 blood samples were subjected to ESR estimation by manual Westergren method and by automated (Ves – Matic) method. Results were analysed, compared and their correlation was calculated using Pearson correlation coefficient. Results: There is a strong positive correlation between Westergren method and Ves- matic 20/20 plus new with correlation coefficient 0.99. Conclusion: Ves-matic method (automated) shows good correlationwith manual Westergren method and is reliable and suitable for use in high work load clinical laboratory. | en_US |
| dc.identifier.affiliations | Assistant Professor, Department of Pathology, Government Medical College, Patiala | en_US |
| dc.identifier.affiliations | Junior Resident, Department of Pathology, Government Medical College, Patiala | en_US |
| dc.identifier.affiliations | Senior resident, Department of Pathology, Government Medical College, Patiala | en_US |
| dc.identifier.affiliations | Professor, Department of Pathology, Government Medical College, Patiala | en_US |
| dc.identifier.citation | Kaur Mohanvir, Mittal Anika, Poonam, Puri Arun. Conventional ESR V/S Automated VES- MATIC 20/20 Plus New ESR- A Comparative Study Of 100 Cases. Annals of International medical and Dental Research. 2018 Mar; 4(2): 34-36 | en_US |
| dc.identifier.issn | 2395-2822 | |
| dc.identifier.issn | 2395-2814 | |
| dc.identifier.place | India | en_US |
| dc.identifier.uri | https://imsear.searo.who.int/handle/123456789/188552 | |
| dc.language | en | en_US |
| dc.publisher | Society for Health Care & Research Development | en_US |
| dc.relation.issuenumber | 2 | en_US |
| dc.relation.volume | 4 | en_US |
| dc.source.uri | https://doi.org/10.21276/aimdr.2018.4.2.PT8 | en_US |
| dc.title | Conventional ESR V/S Automated VES- MATIC 20/20 Plus New ESR- A Comparative Study Of 100 Cases | en_US |
| dc.type | Journal Article | en_US |
Files
Original bundle