Drug-Eluting Stent (DES) Induced Coronary Artery Aneurysm - A Case Report.

dc.contributor.authorChoudhury, A K
dc.contributor.authorAkhtaruzzaman, M
dc.contributor.authorKhalequzzaman, M
dc.contributor.authorHasem, S
dc.contributor.authorChoudhury, T A
dc.contributor.authorSharafat, N I
dc.date.accessioned2015-12-16T06:47:33Z
dc.date.available2015-12-16T06:47:33Z
dc.date.issued2013
dc.description.abstractDrug-eluting stents (DES), which locally elute antiproliferative drugs, can dramatically inhibit neointimal growth. However, several pathological studies have indicated that DES may delay healing after vascular injury, and DES implantation may be theoretically associated with a risk of coronary artery aneurysm formation. Coronary aneurysms have been reported from 3 days to up to 4 years after DES implantation procedures, with varying clinical presentations. Mr. X, 60 years old diabetic, hypertensive got admitted in NICVD and was diagnosed as a case of Chronic Stable Angina. His ETT was strongly positive, CAG showed significant long lesion in LAD. Direct stenting with DES to LAD done and whole procedure was uneventful. After 10 days of PCI patient got readmitted in hospital with complaints of chest discomfort with high grade fever for 2 days. ECG showed AMI (Extensive Anterior) indicating involvement of LAD territory with strong suspicion of Sub Acute Stent Thrombosis (SAST). Streptokinase could not be given due to delayed arrival. Patient was treated conservatively with Low Molecular Weight Heparin. Check CAG was done 7 days after readmission showing Patent stent in LAD with aneurysmal dilatation at the distal end of stent in LAD. The objective of this case report is to focus on the rare but not uncommon incidence of stent implantation.en_US
dc.identifier.citationChoudhury A K, Akhtaruzzaman M, Khalequzzaman M, Hasem S, Choudhury T A, Sharafat N I. Drug-Eluting Stent (DES) Induced Coronary Artery Aneurysm - A Case Report. Cardiovascular Journal. 2013; 6(1): 63-67.en_US
dc.identifier.issn2071-0917
dc.identifier.issn2309-6357
dc.identifier.urihttps://imsear.searo.who.int/handle/123456789/168279
dc.language.isoenen_US
dc.source.urihttps://banglajol.info/index.php/CARDIO/article/view/16118en_US
dc.subjectCoronary artery aneurysmen_US
dc.subjectDESen_US
dc.titleDrug-Eluting Stent (DES) Induced Coronary Artery Aneurysm - A Case Report.en_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
cd2013v6n1p63.pdf
Size:
200.2 KB
Format:
Adobe Portable Document Format
Description:
Case report
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: