Venogram-guided extrathoracic subclavian vein puncture.

dc.contributor.authorDora, Santosh Kumaren_US
dc.contributor.authorKumar, V K Ajithen_US
dc.contributor.authorBhat, Anilen_US
dc.contributor.authorTharakan, Jaganmohan Aen_US
dc.date.accessioned2003-11-03en_US
dc.date.accessioned2009-05-27T04:17:30Z
dc.date.available2003-11-03en_US
dc.date.available2009-05-27T04:17:30Z
dc.date.issued2003-11-03en_US
dc.description.abstractBACKGROUND: Subclavian vein puncture is commonly performed to insert the pacing lead for permanent pacemaker implantation. Our aim was to study the safety and feasibility of venogram-guided extrathoracic subclavian vein puncture for permanent pacemaker lead insertion. METHODS AND RESULTS: Sixty patients (32 males, and 28 females) underwent permanent pacemaker lead insertion by extrathoracic subclavian vein puncture at our institute between March 2002 and December 2002. Fifteen patients underwent dual-chamber and 45 single-chamber pacemaker implantation. All the patients underwent extrathoracic subclavian vein puncture guided by venogram, except 1 who underwent dual-chamber pacemaker implantation in whom the ventricular lead insertion was via the cephalic vein on an elective basis. The procedure was successful in all the patients. Inadvertent subclavian artery puncture occurred in 2 patients without any complication. There was no incidence of pneumothorax, hemothorax or pacemaker site infection. CONCLUSIONS: Venogram-guided extrathoracic subclavian vein puncture is safe and successful. It may be adopted as one of the preferred approaches for permanent pacemaker lead insertion.en_US
dc.description.affiliationDepartment of Cardiology, Sree Chitra Tirunal Institute of Medical Sciences and Technology, Thiruvananthapuram. kskdora@hotmail.comen_US
dc.identifier.citationDora SK, Kumar VK, Bhat A, Tharakan JA. Venogram-guided extrathoracic subclavian vein puncture. Indian Heart Journal. 2003 Nov-Dec; 55(6): 637-40en_US
dc.identifier.urihttps://imsear.searo.who.int/handle/123456789/2854
dc.language.isoengen_US
dc.source.urihttps://indianheartjournal.comen_US
dc.subject.meshAdolescenten_US
dc.subject.meshAdulten_US
dc.subject.meshAgeden_US
dc.subject.meshChilden_US
dc.subject.meshContrast Mediaen_US
dc.subject.meshElectrodes, Implanteden_US
dc.subject.meshFemaleen_US
dc.subject.meshHumansen_US
dc.subject.meshMaleen_US
dc.subject.meshMiddle Ageden_US
dc.subject.meshPacemaker, Artificialen_US
dc.subject.meshPhlebography --instrumentationen_US
dc.subject.meshPhlebotomy --instrumentationen_US
dc.subject.meshProspective Studiesen_US
dc.subject.meshProsthesis Implantation --adverse effectsen_US
dc.subject.meshSubclavian Vein --radiographyen_US
dc.titleVenogram-guided extrathoracic subclavian vein puncture.en_US