Intraobserver and interobserver reproducibility of the FAB classification in acute leukaemia.

No Thumbnail Available
Date
1992-07-01
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
Intraobserver and interobserver reproducibility of FAB classification for acute leukaemia was assessed using the modified criteria of the FAB classification. Leishman stained peripheral smear and May Grunwald Giemsa stained bone marrow smears from 72 cases of acute leukaemia were used for this purpose. Cytochemical stains used were peroxidase, PAS and Sudan black B. Intraobserver and interobserver concordance/discordance was calculated. Kappa statistic was used to correct the chance expected agreement. Intraobserver and interobserver concordance was 76% which improved to 91% when cytochemistry was included. Lymphocytic/Nonlymphocytic concordance was 87.5% and 90% respectively for intraobserver and interobserver groups.
Description
Keywords
Citation
Chudgar U, Khanduri U. Intraobserver and interobserver reproducibility of the FAB classification in acute leukaemia. Indian Journal of Pathology & Microbiology. 1992 Jul; 35(3): 229-36