Anterior chamber depth and lens thickness in primary angle-closure glaucoma: a case-control study.

No Thumbnail Available
Date
1993-07-01
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
Anterior chamber depth and lens thickness have been considered as important biometric determinants in primary angle-closure glaucoma (PACG). In a tertiary care centre-based case-control study, 70 patients and equal number of controls were investigated to analyse the strength of association and predictability of anterior chamber depth (ACD) and lens thickness (LT) in the disease. Mean (+/- S.D.) ACD and LT in the cases and the controls were found to be 2.28 +/- 0.19, 2.87 +/- 0.10; 4.57 +/- 0.34 and 4.13 +/- 0.19 mm respectively. Two sample t test demonstrated statistically significant difference in the ACD and LT between the cases and the controls (Difference being -0.59, 0.44; 95% confidence interval of the difference: -0.64, -0.53 and 0.34, 0.53 respectively, P < 0.01). Logistic regression analysis demonstrated statistically significant protective effect of ACD over PACG (P < 0.01). The odds ratio corresponding to an increase of 0.01 mm in ACD and LT were computed as 0.83 and 1.11 respectively.
Description
Keywords
Citation
Saxena S, Agrawal PK, Pratap VB, Nath R. Anterior chamber depth and lens thickness in primary angle-closure glaucoma: a case-control study. Indian Journal of Ophthalmology. 1993 Jul; 41(2): 71-3