M-shaped doppler signal across ventricular septal defect: potential implications for estimation of right ventricuilar systolic pressure.

No Thumbnail Available
Date
2005-03-15
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
An 8-year-old child suffering from ventricular septal defect and severe valvular pulmonary stenosis was evaluated by echo-Doppler technique and cardiac catheterization. A peak instantaneous transventricular systolic gradient of 64 mmHg was recorded across the ventricular septal defect with an interesting M-shaped spectral pattern. However, cardiac catheterization revealed a peak-to-peak non-simultaneous gradient between the right and the left ventricle of only 14 mmHg. This discrepancy along with its implications are discussed in this report.
Description
Keywords
Citation
Mohan JC, Nath LR. M-shaped doppler signal across ventricular septal defect: potential implications for estimation of right ventricuilar systolic pressure. Indian Heart Journal. 2005 Mar-Apr; 57(2): 158-60