Comparison of blood specimens from plain and gel vacuum blood collection tubes.

No Thumbnail Available
Date
2001-05-19
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
This study was set in the Division of Laboratory Medicine, Chulalongkorn Hospital. All 2,000 blood specimens were randomly collected using evacuated blood collection by plain or gel vacuum tubes. After collection, each specimen was considered and judged using criteria of specimen rejection to determine how proper the specimen presentations were. All data were reviewed, collected and interpreted. It revealed that there were only 20 (1%) improper specimens and all were improper in quality. There was no significant difference between the ratio of improper specimens in both groups (P > 0.30). From this study, it revealed that efficacy of both types of vacuum tubes was not different. The new gel vacuum tube seems to be an effective tool in the evacuated blood collection system due to its advantage in reduction of time in specimen processing.
Description
Chotmaihet Thangphaet.
Keywords
Citation
Wiwanitkit V. Comparison of blood specimens from plain and gel vacuum blood collection tubes. Journal of the Medical Association of Thailand. 2001 May; 84(5): 723-6