Transcatheter coil occlusion of persistent ductus arteriosus using detachable steel coils: short-term results.

No Thumbnail Available
Date
1997-01-01
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
Twenty patients underwent transcatheter occlusion of persistent ductus arteriosus (PDA), 1.5-5.5 mm in diameter, with detachable steel coils. A coil having a diameter at least twice that of the narrowest ductal diameter was used. Procedural success was achieved in all, using a single coil in 14 and multiple coils in the remaining 6. At follow-up after 2-12 (6.7 +/- 2.8) months, continuous murmur persisted in only one patient, while 4 (20%) patients had residual shunt on Doppler colour-flow imaging. There was no instance of coil embolisation, thromboembolism, intravascular haemolysis, local vascular complication or sepsis. Transcatheter occlusion of PDA with detachable coils is a safe, technically easy and cost-effective method with the added advantage of feasibility in small children.
Description
Keywords
Citation
Arora R, Verma PK, Trehan V, Passey R, Nigam M, Kalra GS. Transcatheter coil occlusion of persistent ductus arteriosus using detachable steel coils: short-term results. Indian Heart Journal. 1997 Jan-Feb; 49(1): 60-4