Oblique Percutaneous In-Situ Cannulated Screw Fixation Of Stable Slipped Capital Femoral Epiphysis- Our Surgical Experience

Loading...
Thumbnail Image
Date
2018-04
Journal Title
Journal ISSN
Volume Title
Publisher
World Wide Journals
Abstract
Introduction: The percutaneous in-situ pinning perpendicular to the physis has been described as the standard technique for fixing mild to moderate stable Slipped capital femoral epiphysis. In this study we are going to discuss about our results using an alternative anterolateral oblique pinning technique for SCFE. Methods: We treated 10 patients by this technique from June 2015 to May 2017. The average age of the patients was 12 years with the range between 10 to 15 years. Only mild to moderate slips as measured by Southwick angle of less than 60 degrees in frog leg lateral view were included in this study. Results: None of the patients developed complications like screw penetration, AVN, chondrolysis, slip progression or breakage of screw. There was restriction of terminal 10 degrees abduction in 6 patients and obligatory external rotation on hip flexion in 3 patients. Conclusion: To conclude anterolaterally based insitu oblique screw fixation is a relatively easier technique providing better stability without risk of complications.
Description
Keywords
Slipped capital femoral epiphysis (SCFE), percutaneous in-situ pinning, oblique screw fixation
Citation
Karthi MN, Ramanathan Ashok Kumar. Oblique Percutaneous In-Situ Cannulated Screw Fixation Of Stable Slipped Capital Femoral Epiphysis- Our Surgical Experience. International Journal of Scientific Research. 2018 Apr; 7(4): 6-7