Repair of recurrent pseudoaneurysm of the mitral-aortic intervalvular fibrosa: Role of transesophageal echocardiography.

Abstract
Pseudoaneurysm of mitral‑aortic intervalvular fibrosa (P‑MAIVF) is a rare cardiac surgical condition. P‑MAIVF commonly occurs as a complication of aortic and mitral valve replacement surgeries. The surgical trauma during replacement of the valves weakens the avascular mitral and aortic intervalvular area. We present a case of P‑MAIVF recurrence 5 years after a primary repair. Congestive cardiac failure was the presenting feature with mitral and aortic regurgitation. In view of the recurrence, the surgical team planned for a double valve replacement. The sewing rings of the two prosthetic‑valves were interposed to close the mouth of the pseudoaneurysm and to provide mechanical reinforcement of the MAIVF. Intra‑operative transesophageal echocardiography (TEE) helped in delineating the anatomy, extent of the lesion, rupture of one of the pseudoaneurysm into left atrium and severity of the valvular regurgitation. Post‑procedure TEE confirmed complete obliteration of the pseudoaneurysm and prosthetic valve function.
Description
Keywords
Double‑valve replacement, Mitral‑aortic intervalvular fibrosa, Pseudoaneurysm, Transesophageal echocardiography
Citation
Joshi Shreedhar S, Thimmarayappa Ashwini, Nagaraja P S, Jagadeesh A M, Furtado Arul, Bhat Seetharam. Repair of recurrent pseudoaneurysm of the mitral-aortic intervalvular fibrosa: Role of transesophageal echocardiography. Annals of Cardiac Anaesthesia. 2014 Apr; 17(2): 152-154.