Sequencing Batch Reactor (SBR) treatment for simultaneous organic carbon and nitrogen removal--a laboratory study.

No Thumbnail Available
Date
2006-07-06
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
The performance of a laboratory-scale Sequencing Batch Reactor (SBR) has been studied in aerobic-anoxic sequence for simultaneous organic carbon and nitrogen removal. The reactor was operated under three different variations of aerobic-anoxic sequence, viz. 4+4, 5+3 and 3+5 hours with input solutions of soluble COD (SCOD) level 1000 +/- 100 mg/L and initial ammonia nitrogen of 40 and 90 mg/L. It has been observed that 85 to 92% of SCOD removal would be possible at the end of 8.0 hour of overall reaction period, irrespective of the length of the aerobic react period. In the case of 4+4 hour operating cycle, reasonable degree of nitrification (88-100%) and denitrification (73-75%), along with 91-94% of organic carbon removal have been achieved, which has been considered to be the optimum performance of the reactor.
Description
Keywords
Citation
Debsarkar A, Mukherjee S, Datta S. Sequencing Batch Reactor (SBR) treatment for simultaneous organic carbon and nitrogen removal--a laboratory study. Journal of Environmental Science & Engineering. 2006 Jul; 48(3): 169-74